15.6” Industrial Display for Control Panels | OPX-156
VINCANWO GROUP
Availability: | |
---|---|
Quantity: | |
SKU | OPX-156 |
Screen Size | 15.6" |
Resolution | 1366*768 |
Viewing Angle | 45/45/20/40 |
Brightness | 200 cd/m2 |
Contrast Ratio | 500:1 |
Touch Screen | Capacitive |
Controller | USB interface |
Durability | ≥ 5M times |
USB | 1 *USB (For touchscreen cable) |
Display | 1 *HDMI, 1 *VGA |
Dimensions (mm) | 392.04*242*49.5mm |
Mounting Hole Sizes (mm) | 387.2*237.2mm |
Individual Gross Weight (KG) | 3.70kg |
Mounting Options | Embedded / Wall-mounted / Desktop |
Operating Temperature | -30 ~ +70℃ |
Storage Temperature | -40 ~ +80℃ |
Storage Humidity *Non-condensing | 5% ~ 95% |
Power Input | 12V DC (3A) <Option Wide-range 9 ~ 36V DC Power Input> |
Packaging Information | 1 *Master, 1 *Adapter, 1* Power Supply Cable, 1 *Touch Screen Cable, 1 *VGA cable, 1 *Manual, 1 *Warranty Card |
Feature | OPX-156 Specifications |
---|---|
Display | 15.6" IPS LCD (16:9 aspect ratio) |
Resolution | 1920×1080 (FHD) or 1366×768 (HD) |
Brightness | 400–1000 cd/m²(auto-dimming to 1 cd/m²) |
Touch Technology | 5-Wire Resistive (glove/wet operation) or Projected Capacitive (10-pt multitouch) |
Operating Temp | -30°C to +70°C (fanless, aluminum heatspreader) |
Ingress Protection | IP66/NEMA 4X front(panel-mounted) |
Panel Cutout | 362.0 × 246.0 mm (VESA 100×100 compatible) |
Construction | 5mm chemically-tempered glass + stainless steel bezel |
Power Input | 24V DC (9–36V) or PoE+ (802.3at) |
Power Consumption | 12W typical (idle: 1.5W, peak: 25W) |
Mechanical Optimization
Flush-Mount Design: <3mm front protrusion (meets ANSI/UL 50E Type 4X)
Tool-Free Clamps: Stainless steel retention brackets (20–50mm panel thickness)
Gasket Material: EPDM rubber (IP66 sealing @ -40°C to 120°C)
Environmental Ruggedness
Vibration Resistance: 5Grms (IEC 60068-2-6)
Chemical Resistance: Front surface withstands oils, solvents, and cleaning agents (per ISO 2812-2)
Optical Bonding: Standard (eliminates internal fogging, boosts contrast 2.5×)
Electrical Safety
Isolated I/O: 4× 24V digital inputs (2kV isolation), 2× RS-485 (2.5kV isolation)
Surge Protection: 6kV/500A surge on power lines (IEC 61000-4-5)
Interface | Control Panel Use Case |
---|---|
Fieldbus | PROFINET, EtherNet/IP via embedded OPC UA gateway |
PLC I/O | 2× isolated analog inputs (0–10V/4–20mA), 4× relay outputs (24V@2A) |
Video/Control | HDMI 1.4, USB 2.0 (host/device), RS-232 |
Expansion | OPS slot (supports Intel Elkhart Lake or ARM modules) |
Safety | 2× SIL 2-certified inputs (EN 62061) |
Machine Tool HMIs: CNC operator panels (ISO 13849 PLc)
Process Skids: Chemical dosing control (NEMA 4X washdown)
Power Distribution: Switchgear monitoring (IEC 61439-2)
Water Treatment: SCADA local operator stations (NSF/ANSI 61)
Parameter | Legacy 15" Panel | OPX-156 |
---|---|---|
Bezel Width | 25–30mm | 12mm (ultra-slim) |
Viewing Area | 337×269 mm | 344×193 mm (16:9 FHD) |
Power per Nit | 0.07W/nit | 0.03W/nit |
Retrofit Time | 2+ hours (re-cutting) | <30 min(drop-in) |
Mechanical Installation
Gasket Compression: Apply 8–12 N·m torque on mounting bolts (prevents over-compression)
EMI Sealing: Use EMI finger stock (Laird 420-10-0-00) between bezel/panel
Electrical Integration
Grounding: Star-point ground to chassis with AWG 12 wire (IEC 61439-2)
PoE+ Budgeting: Max 25.5W per port (use TL-SG1016PE industrial switch)
Environmental Protection
Washdown Prep: Apply silicone sealant(Dow Corning 732) around cable glands
UV Resistance: For outdoor use, specify anti-UV coating (prevents yellowing)
Factor | OPX-156 Advantage |
---|---|
Energy Savings | $165/year (vs. 300-nit legacy @ 24/7 ops) |
Retrofit Labor | $220 saved (no panel re-cutting) |
Maintenance | Zero backlight replacement(LED lifespan = 100k hours) |
Lifecycle | 10-year hardware support guarantee |
SKU | OPX-156 |
Screen Size | 15.6" |
Resolution | 1366*768 |
Viewing Angle | 45/45/20/40 |
Brightness | 200 cd/m2 |
Contrast Ratio | 500:1 |
Touch Screen | Capacitive |
Controller | USB interface |
Durability | ≥ 5M times |
USB | 1 *USB (For touchscreen cable) |
Display | 1 *HDMI, 1 *VGA |
Dimensions (mm) | 392.04*242*49.5mm |
Mounting Hole Sizes (mm) | 387.2*237.2mm |
Individual Gross Weight (KG) | 3.70kg |
Mounting Options | Embedded / Wall-mounted / Desktop |
Operating Temperature | -30 ~ +70℃ |
Storage Temperature | -40 ~ +80℃ |
Storage Humidity *Non-condensing | 5% ~ 95% |
Power Input | 12V DC (3A) <Option Wide-range 9 ~ 36V DC Power Input> |
Packaging Information | 1 *Master, 1 *Adapter, 1* Power Supply Cable, 1 *Touch Screen Cable, 1 *VGA cable, 1 *Manual, 1 *Warranty Card |
Feature | OPX-156 Specifications |
---|---|
Display | 15.6" IPS LCD (16:9 aspect ratio) |
Resolution | 1920×1080 (FHD) or 1366×768 (HD) |
Brightness | 400–1000 cd/m²(auto-dimming to 1 cd/m²) |
Touch Technology | 5-Wire Resistive (glove/wet operation) or Projected Capacitive (10-pt multitouch) |
Operating Temp | -30°C to +70°C (fanless, aluminum heatspreader) |
Ingress Protection | IP66/NEMA 4X front(panel-mounted) |
Panel Cutout | 362.0 × 246.0 mm (VESA 100×100 compatible) |
Construction | 5mm chemically-tempered glass + stainless steel bezel |
Power Input | 24V DC (9–36V) or PoE+ (802.3at) |
Power Consumption | 12W typical (idle: 1.5W, peak: 25W) |
Mechanical Optimization
Flush-Mount Design: <3mm front protrusion (meets ANSI/UL 50E Type 4X)
Tool-Free Clamps: Stainless steel retention brackets (20–50mm panel thickness)
Gasket Material: EPDM rubber (IP66 sealing @ -40°C to 120°C)
Environmental Ruggedness
Vibration Resistance: 5Grms (IEC 60068-2-6)
Chemical Resistance: Front surface withstands oils, solvents, and cleaning agents (per ISO 2812-2)
Optical Bonding: Standard (eliminates internal fogging, boosts contrast 2.5×)
Electrical Safety
Isolated I/O: 4× 24V digital inputs (2kV isolation), 2× RS-485 (2.5kV isolation)
Surge Protection: 6kV/500A surge on power lines (IEC 61000-4-5)
Interface | Control Panel Use Case |
---|---|
Fieldbus | PROFINET, EtherNet/IP via embedded OPC UA gateway |
PLC I/O | 2× isolated analog inputs (0–10V/4–20mA), 4× relay outputs (24V@2A) |
Video/Control | HDMI 1.4, USB 2.0 (host/device), RS-232 |
Expansion | OPS slot (supports Intel Elkhart Lake or ARM modules) |
Safety | 2× SIL 2-certified inputs (EN 62061) |
Machine Tool HMIs: CNC operator panels (ISO 13849 PLc)
Process Skids: Chemical dosing control (NEMA 4X washdown)
Power Distribution: Switchgear monitoring (IEC 61439-2)
Water Treatment: SCADA local operator stations (NSF/ANSI 61)
Parameter | Legacy 15" Panel | OPX-156 |
---|---|---|
Bezel Width | 25–30mm | 12mm (ultra-slim) |
Viewing Area | 337×269 mm | 344×193 mm (16:9 FHD) |
Power per Nit | 0.07W/nit | 0.03W/nit |
Retrofit Time | 2+ hours (re-cutting) | <30 min(drop-in) |
Mechanical Installation
Gasket Compression: Apply 8–12 N·m torque on mounting bolts (prevents over-compression)
EMI Sealing: Use EMI finger stock (Laird 420-10-0-00) between bezel/panel
Electrical Integration
Grounding: Star-point ground to chassis with AWG 12 wire (IEC 61439-2)
PoE+ Budgeting: Max 25.5W per port (use TL-SG1016PE industrial switch)
Environmental Protection
Washdown Prep: Apply silicone sealant(Dow Corning 732) around cable glands
UV Resistance: For outdoor use, specify anti-UV coating (prevents yellowing)
Factor | OPX-156 Advantage |
---|---|
Energy Savings | $165/year (vs. 300-nit legacy @ 24/7 ops) |
Retrofit Labor | $220 saved (no panel re-cutting) |
Maintenance | Zero backlight replacement(LED lifespan = 100k hours) |
Lifecycle | 10-year hardware support guarantee |