Storage Server Systems | ST Series
VINCANWO GROUP
Availability: | |
---|---|
Quantity: | |
Model | ST-T208 | ST-T212 | ST-T316 | ST-T424 | ST-T2125 |
Appearance specifications | 2U 8 rotors | 2U 12 rotors | 3U 16 rotors | 4U 24 rotors | 2U 25 rotors |
Controller | |||||
RAID level | 0 ,1 ,5 ,6 ,10 ,50 ,60.、JBOD | ||||
Host Connection | |||||
Management Port | Gigabit Ethernet IPMI2.0 | ||||
Applicable platforms | Windows ,Linux ,Solaris ,HP-UX ,VMware ,MAC OS ,AIX | ||||
Storage Media | |||||
Disk Expansion | Direct Connection | Direct Connection, Extension | Extended Mode | Extended Mode | Extended Mode |
Number of Disks | 8 (Optional) | 12 (Optional) | 16 (Optional) | 24 (Optional) | 25 (Optional) |
Storage Capacity | SAS3: | SAS3: | SAS3: | SAS3: | SAS3: |
Max 192TB | Max 288TB | MAX 384TB | Max 576TB | Max 600TB | |
SATA3: | SATA3: | SATA3: | SATA3: | SATA3: | |
Max 192TB | Max 288TB | MAX 384TB | Max 576TB | Max 600TB | |
Hard disk specifications | 2. 5" 300GB/600GB/1.2TB/2.4TB SAS3 Hard Disk | ||||
3. 5" 2TB/4TB/6TB/8T/10T /12TB/14TB/16TB/18TB/20TB/24TB/SAS3 Hard Disk | |||||
3. 5" 2TB/4TB/6TB/8T/10T /12TB/14TB/16TB/18TB/20TB/24TB/SATA3 Hard Disk | |||||
Supports enterprise level SSDs (no need to replace hard drive bays) | |||||
Management Function | |||||
System Management | SkyTalent Storage system management software | ||||
Supports B/S architecture and can be managed through a web interface | |||||
Network Management | Supports SNMP, Email alerts | ||||
Support management interface alarms, Support daily record information export | |||||
Storage Management | Front end management based on display and serial port | ||||
Web browser based remote management method (SSL based secure connection) | |||||
Multiple RAID levels and stripe sizes | |||||
Local and global hot spare, supporting configuration of multiple global hot spare disks | |||||
Online hard disk transfer and array roaming | |||||
Hard disk SMART | |||||
Energy Saving Management | Support MAID, System energy saving 20% ~ 30% | ||||
Path Management | |||||
Data Management | |||||
General Characteristics | |||||
System Power Supply | Redundance 550W | Redundance 800W | Redundance 800/1200W | Redundance 800/1200W | Redundance 800/1200W |
Power Supply Requirements | 100 ~ 240VAC (+/-10%), 47 ~ 63HZ, Auto-Ranging , PFC | ||||
Temperature | Working environment: - 10℃ ~ +35℃, Non-working environment: - 40℃ ~ +70℃ | ||||
Humidity | Working environment: 8% ~ 90% , Non-working 5%~95% |
Ruggedized Hardware Design:
Construction: Heavy-duty steel chassis, vibration-resistant drive mounts.
Cooling: Optimized airflow with industrial-grade fans (often hot-swappable), or fanless designs for lower-density units.
Temperature Range: Extended operation (0°C to 50°C or -10°C to 60°C common; specialized models go wider).
Certifications: CE, FCC, RoHS; often MIL-STD-810G for shock/vibration; NEBS Level 3 (for telecom).
Scalable Storage Capacity:
Tower: 4-12+ bays (3.5"/2.5").
Rackmount (1U-4U): 4-36+ bays (often 12-24 bays in 2U/3U).
JBOD Expansion: Support for external SAS enclosures (e.g., 45-drive units).
Drive Bays: Configurations range widely:
Drive Support: SATA HDD/SSD, SAS HDD/SSD, NVMe U.2 (via dedicated bays or PCIe adapters). Hot-swap backplanes are standard.
Processing Power & Memory:
CPU: Intel Xeon E3/E5 (or newer Xeon Scalable), AMD EPYC, or Intel Core i3/i5/i9. Varies by model tier.
RAM: ECC DDR4/DDR5 support (64GB - 1TB+), critical for data integrity.
Expansion: Multiple PCIe slots (for HBAs, 10GbE/25GbE/100GbE NICs, GPUs, FPGA accelerators).
Connectivity & Networking:
Ethernet: Dual/triple/quad 1GbE ports (base), plus 10GbE SFP+/RJ45, 25GbE, or 100GbEoptions (via onboard or PCIe).
Remote Management: IPMI 2.0+ with dedicated LAN port (for out-of-band management).
High-Speed Storage Fabrics: SAS/SATA ports (for JBOD expansion), NVMe over Fabrics (NVMe-oF) support in higher-end models.
USB: Multiple ports for backup/import.
Data Protection & Redundancy:
RAID Support: Hardware RAID controllers (LSI/Broadcom, Adaptec) with cache/battery protection. Support for RAID 0, 1, 5, 6, 10, 50, 60, 60, JBOD.
Power Supplies: Dual redundant hot-swappable PSUs (80+ Platinum efficiency common).
ECC Memory: Mandatory for server-grade data integrity.
Snapshot/Replication: Often handled at the OS/software level.
Operating System & Software Flexibility:
OS Options: Linux (Ubuntu Server, CentOS, RHEL), Windows Server, FreeNAS/TrueNAS Core, VMware ESXi, Proxmox VE.
Pre-Configured NAS: Some models come with vendor-specific NAS OS (e.g., QNAP QTS, Synology DSM, Asustor ADM).
Feature | Industrial ST Series | Data Center ST Series |
---|---|---|
Environment | Harsh (temp, vibe, dust) | Controlled (AC, low-dust) |
Temp Range | Wider (-20°C to 60°C+) | Standard (5°C to 35°C) |
Certifications | MIL-STD-810G, IP rating optional | NEBS, CE, FCC |
Form Factor | Often ruggedized tower or short-depth rack | Standard rackmount (1U-4U) |
Use Case | Edge, factory floor, mobile/vehicle | Enterprise server room/cloud DC |
InWin (Industrial): ST Series chassis (e.g., ST410, ST510) – popular for custom industrial server builds.
QNAP Systems: TS-x63 series (AMD-based) or TVS-x72XT (Intel/Thunderbolt) – NAS-focused.
Supermicro: SYS-1xxST (Short-Depth) or SC1xx/2xx chassis – broad server/NAS/JBOD options.
Synology: SA Series (Enterprise NAS) – though "ST" is less common.
Dell/EMC: PowerEdge ST models (historical) – check current PowerEdge lineup.
OnLogic (Logic Supply): Custom rugged servers (often use InWin ST chassis).
Workload: Archive? Real-time analytics? Video surveillance? Virtualization?
Capacity & Scalability: Raw TB needed now + future growth (JBOD support?).
Performance: Drive types (HDD vs. SSD vs. NVMe), network speed (10/25/100GbE), CPU/RAM.
Environment: Temp, humidity, vibration specs.
RAID & Redundancy: Hardware RAID level, dual PSUs, ECC RAM.
OS/Software: Compatibility with your applications (e.g., ZFS on TrueNAS).
Management: IPMI/KVM, vendor-specific tools.
Warranty & Support: Industrial vendors often offer 5+ years.
For a precise recommendation, provide the full model number (e.g., ST410-TOWER, QNAP TS-1635AX). The "ST Series" umbrella covers vastly different solutions!
Model | ST-T208 | ST-T212 | ST-T316 | ST-T424 | ST-T2125 |
Appearance specifications | 2U 8 rotors | 2U 12 rotors | 3U 16 rotors | 4U 24 rotors | 2U 25 rotors |
Controller | |||||
RAID level | 0 ,1 ,5 ,6 ,10 ,50 ,60.、JBOD | ||||
Host Connection | |||||
Management Port | Gigabit Ethernet IPMI2.0 | ||||
Applicable platforms | Windows ,Linux ,Solaris ,HP-UX ,VMware ,MAC OS ,AIX | ||||
Storage Media | |||||
Disk Expansion | Direct Connection | Direct Connection, Extension | Extended Mode | Extended Mode | Extended Mode |
Number of Disks | 8 (Optional) | 12 (Optional) | 16 (Optional) | 24 (Optional) | 25 (Optional) |
Storage Capacity | SAS3: | SAS3: | SAS3: | SAS3: | SAS3: |
Max 192TB | Max 288TB | MAX 384TB | Max 576TB | Max 600TB | |
SATA3: | SATA3: | SATA3: | SATA3: | SATA3: | |
Max 192TB | Max 288TB | MAX 384TB | Max 576TB | Max 600TB | |
Hard disk specifications | 2. 5" 300GB/600GB/1.2TB/2.4TB SAS3 Hard Disk | ||||
3. 5" 2TB/4TB/6TB/8T/10T /12TB/14TB/16TB/18TB/20TB/24TB/SAS3 Hard Disk | |||||
3. 5" 2TB/4TB/6TB/8T/10T /12TB/14TB/16TB/18TB/20TB/24TB/SATA3 Hard Disk | |||||
Supports enterprise level SSDs (no need to replace hard drive bays) | |||||
Management Function | |||||
System Management | SkyTalent Storage system management software | ||||
Supports B/S architecture and can be managed through a web interface | |||||
Network Management | Supports SNMP, Email alerts | ||||
Support management interface alarms, Support daily record information export | |||||
Storage Management | Front end management based on display and serial port | ||||
Web browser based remote management method (SSL based secure connection) | |||||
Multiple RAID levels and stripe sizes | |||||
Local and global hot spare, supporting configuration of multiple global hot spare disks | |||||
Online hard disk transfer and array roaming | |||||
Hard disk SMART | |||||
Energy Saving Management | Support MAID, System energy saving 20% ~ 30% | ||||
Path Management | |||||
Data Management | |||||
General Characteristics | |||||
System Power Supply | Redundance 550W | Redundance 800W | Redundance 800/1200W | Redundance 800/1200W | Redundance 800/1200W |
Power Supply Requirements | 100 ~ 240VAC (+/-10%), 47 ~ 63HZ, Auto-Ranging , PFC | ||||
Temperature | Working environment: - 10℃ ~ +35℃, Non-working environment: - 40℃ ~ +70℃ | ||||
Humidity | Working environment: 8% ~ 90% , Non-working 5%~95% |
Ruggedized Hardware Design:
Construction: Heavy-duty steel chassis, vibration-resistant drive mounts.
Cooling: Optimized airflow with industrial-grade fans (often hot-swappable), or fanless designs for lower-density units.
Temperature Range: Extended operation (0°C to 50°C or -10°C to 60°C common; specialized models go wider).
Certifications: CE, FCC, RoHS; often MIL-STD-810G for shock/vibration; NEBS Level 3 (for telecom).
Scalable Storage Capacity:
Tower: 4-12+ bays (3.5"/2.5").
Rackmount (1U-4U): 4-36+ bays (often 12-24 bays in 2U/3U).
JBOD Expansion: Support for external SAS enclosures (e.g., 45-drive units).
Drive Bays: Configurations range widely:
Drive Support: SATA HDD/SSD, SAS HDD/SSD, NVMe U.2 (via dedicated bays or PCIe adapters). Hot-swap backplanes are standard.
Processing Power & Memory:
CPU: Intel Xeon E3/E5 (or newer Xeon Scalable), AMD EPYC, or Intel Core i3/i5/i9. Varies by model tier.
RAM: ECC DDR4/DDR5 support (64GB - 1TB+), critical for data integrity.
Expansion: Multiple PCIe slots (for HBAs, 10GbE/25GbE/100GbE NICs, GPUs, FPGA accelerators).
Connectivity & Networking:
Ethernet: Dual/triple/quad 1GbE ports (base), plus 10GbE SFP+/RJ45, 25GbE, or 100GbEoptions (via onboard or PCIe).
Remote Management: IPMI 2.0+ with dedicated LAN port (for out-of-band management).
High-Speed Storage Fabrics: SAS/SATA ports (for JBOD expansion), NVMe over Fabrics (NVMe-oF) support in higher-end models.
USB: Multiple ports for backup/import.
Data Protection & Redundancy:
RAID Support: Hardware RAID controllers (LSI/Broadcom, Adaptec) with cache/battery protection. Support for RAID 0, 1, 5, 6, 10, 50, 60, 60, JBOD.
Power Supplies: Dual redundant hot-swappable PSUs (80+ Platinum efficiency common).
ECC Memory: Mandatory for server-grade data integrity.
Snapshot/Replication: Often handled at the OS/software level.
Operating System & Software Flexibility:
OS Options: Linux (Ubuntu Server, CentOS, RHEL), Windows Server, FreeNAS/TrueNAS Core, VMware ESXi, Proxmox VE.
Pre-Configured NAS: Some models come with vendor-specific NAS OS (e.g., QNAP QTS, Synology DSM, Asustor ADM).
Feature | Industrial ST Series | Data Center ST Series |
---|---|---|
Environment | Harsh (temp, vibe, dust) | Controlled (AC, low-dust) |
Temp Range | Wider (-20°C to 60°C+) | Standard (5°C to 35°C) |
Certifications | MIL-STD-810G, IP rating optional | NEBS, CE, FCC |
Form Factor | Often ruggedized tower or short-depth rack | Standard rackmount (1U-4U) |
Use Case | Edge, factory floor, mobile/vehicle | Enterprise server room/cloud DC |
InWin (Industrial): ST Series chassis (e.g., ST410, ST510) – popular for custom industrial server builds.
QNAP Systems: TS-x63 series (AMD-based) or TVS-x72XT (Intel/Thunderbolt) – NAS-focused.
Supermicro: SYS-1xxST (Short-Depth) or SC1xx/2xx chassis – broad server/NAS/JBOD options.
Synology: SA Series (Enterprise NAS) – though "ST" is less common.
Dell/EMC: PowerEdge ST models (historical) – check current PowerEdge lineup.
OnLogic (Logic Supply): Custom rugged servers (often use InWin ST chassis).
Workload: Archive? Real-time analytics? Video surveillance? Virtualization?
Capacity & Scalability: Raw TB needed now + future growth (JBOD support?).
Performance: Drive types (HDD vs. SSD vs. NVMe), network speed (10/25/100GbE), CPU/RAM.
Environment: Temp, humidity, vibration specs.
RAID & Redundancy: Hardware RAID level, dual PSUs, ECC RAM.
OS/Software: Compatibility with your applications (e.g., ZFS on TrueNAS).
Management: IPMI/KVM, vendor-specific tools.
Warranty & Support: Industrial vendors often offer 5+ years.
For a precise recommendation, provide the full model number (e.g., ST410-TOWER, QNAP TS-1635AX). The "ST Series" umbrella covers vastly different solutions!